HOT AIR OVEN
MAKE- GEOAXIS MODEL NO – HO95 SPECIFICATION To heat soil sample. Should be able attain temperature 50 to 250 degree Celsius ±1 Celsius. Inside size 450 ×600×450 mm×mm×mm.
MAKE- GEOAXIS MODEL NO – HO95 SPECIFICATION To heat soil sample. Should be able attain temperature 50 to 250 degree Celsius ±1 Celsius. Inside size 450 ×600×450 mm×mm×mm.
MAKE- GEOAXIS MODEL NO – CBR85 SPECIFICATION Standards IS:9669, IS:2720 (Part 16) Load Frame, 50 kN (5,000kgf), Capacity, Three Speed 1.5,1.25, 2.5 mm/min Mould – Gun Metal, 150m ID x 175 mm H. Perforated Base Plate – Gun Metal, for Mould. Extension Collar – Gun Metal 150 mm ID x 50 mm high. Penetration Piston
COMPUTERISED CALIFORNIA BEARING RATIO MACHINE Read More »
MAKE- GEOAXIS MODEL NO – SP34 SPECIFICATION Proctor mould having a capacity of 944 cc with an internal diameter of 10.2 cm and a height of 11.6 cm. The mould shall have a detachable collar assembly and a detachable base plate. Rammer: A mechanical operated metal rammer having a 5.08 cm diameter face and a
STANDARD PROCTOR COMPACTION Read More »
MAKE- GEOAXIS MODEL NO – PA33 SPECIFICATION As per Standards IS:2720 (Part 17), IS:11209 Constant Head Permeameter and Falling Head Permeameter Falling Head Permeameters for testing remoulded or undisturbed fine grained soil having less than 10·2 cm/sec coefficient of permeability and Constant Head Permeameters for coarse grained cohesion less soils.
LABORATORY PERMEABILITY APPARATUS Read More »
MAKE- GEOAXIS MODEL NO – CC9 SPECIFICATION Cylindrical Core-Cutter of seamless steel tube, 130 mm long and IO cm internal diameter, with a wall thickness of 3 mm, hevelled at one end, Steel Dolley2.5 cm high and IO cm internal diameter with a wall thickness of 7’5 mm with a lip to enable it
MAKE- GEOAXIS MODEL NO – IMM70 SPECIFICATION To find out water content of soil The infrared moisture meter should be able to operate on 220 Volts AC supply. The apparatus should be completely automatic and to provides % moisture loss through entire drying cycle. The Heating arrangement should consist of 250 watts heating lamp with
INFRARED MOISTURE METER Read More »
MAKE- GEOAXIS MODEL NO – AT85 SPECIFICATION To determine shear strength parameters As per IS 2720 part 11 & part 12 it should be made from corrosion resistant material. The cell cylinders are made from acrylic plastic material and those for use up to 20 bar are usually reinforced by bands. The testing specimen
AUTOMATIC TRIAXIAL TEST APPARATUS Read More »
MAKE- GEOAXIS MODEL NO – DST300 SPECIFICATION To find out shear strength of soilThe apparatus should consist of square divided in to two halves .The specimen , contained in thebox, is subjected to a constant load normal load while an increasing horizontal force is appliedone of the section of the shear box. Theloading unit as
DIRECT SHEAR TEST APPARATUS Read More »
MAKE- GEOAXIS MODEL NO – DST300 SPECIFICATION To find out shear strength of soil The apparatus should consist of square divided in to two halves .The specimen , contained in the box, is subjected to a constant load normal load while an increasing horizontal force is applied one of the section of the shear box.
DIRECT SHEAR TEST APPARATUS Read More »
MAKE- GEOAXIS MODEL NO – SPC60 SPECIFICATION The sand pouring cylinder (small) is suitable for conducting field density estimation of fine and medium grained soils. It should confirm to IS: 2720 (Part XXVIII). The apparatus should consists of followings:- Sand Pouring Cylinder, 115 mm internal dia with conical funnel and shutter. Calibrating Container, 100 mm
SAND POURING CYLINDER (SMALL) Read More »